Document Number: 001-15029 Rev. *G Page 21 of 31
I
SB4
Automatic CE power-down
current – TTL inputs
V
DD
= Max, device deselected,
V
IN
V
DD
– 0.3 V or V
IN
0.3 V,
f = 0, inputs static
7.5 ns cycle,
133 MHz
–165mA
Electrical Characteristics (continued)
Over the Operating Range
Parameter
[15, 16]
Description Test Conditions Min Max Unit
Capacitance
Parameter
[18]
Description Test Conditions
100-pin TQFP
Package
165-ball FBGA
Package
Unit
C
ADDRESS
Address input capacitance T
A
= 25C, f = 1 MHz,
V
DD
= 3.3 V, V
DDQ
= 2.5 V
6 6 pF
C
DATA
Data input capacitance 5 5 pF
C
CTRL
Control input capacitance 8 8 pF
C
CLK
Clock input capacitance 6 6 pF
C
I/O
I/O capacitance 5 5 pF
Thermal Resistance
Parameter
[18]
Description Test Conditions
100-pin TQFP
Max
165-ball FBGA
Max
Unit
JA
Thermal resistance
(junction to ambient)
Test conditions follow standard test methods
and procedures for measuring thermal
impedance, according to EIA/JESD51.
24.63 16.3 C/W
JC
Thermal resistance
(junction to case)
2.28 2.1 C/W
AC Test Loads and Waveforms
Figure 5. AC Test Loads and Waveforms
OUTPUT
R = 317
R = 351
5pF
INCLUDING
JIG AND
SCOPE
(a)
(b)
OUTPUT
R
L
= 50
Z
0
= 50
V
L
= 1.5 V
3.3 V
ALL INPUT PULSES
V
DDQ
GND
90%
10%
90%
10%
1 ns
1 ns
(c)
OUTPUT
R = 1667
R = 1538
5pF
INCLUDING
JIG AND
SCOPE
(a)
(b)
OUTPUT
R
L
= 50
Z
0
= 50
V
L
= 1.25 V
2.5 V
ALL INPUT PULSES
V
DDQ
GND
90%
10%
90%
10%
1 ns
1 ns
(c)
3.3 V I/O Test Load
2.5 V I/O Test Load
Note
18. Tested initially and after any design or process change that may affect these parameters.