CY7C601xx
CY7C602xx
Document 38-16016 Rev. *C Page 39 of 62
P2 Configuration
P3 Configuration
P4 Configuration
Table 60.P2 Configuration (P2CR) [0x15] [R/W]
Bit # 7 6 5 4 3 2 1 0
Field Reserved Int Enable Int Act Low TTL Thresh High Sink Open Drain Pull Up Enable Output Enable
Read/Write –R/WR/WR/WR/W R/W R/W R/W
Default 00000000
In CY7C602xx this register controls the operation of pins P2.0–P2.1. In the CY7C601xx, this register controls the operation of
pins P2.0–P2.7.
The 50-mA sink drive capability is only available on pin P2.7 and only on the CY7C601xx. In the CY7C602xx, only 8-mA sink
drive capability is available on this pin regardless of the setting of the High Sink bit.
Table 61.P3 Configuration (P3CR) [0x16] [R/W]
Bit # 7 6 5 4 3 2 1 0
Field Reserved Int Enable Int Act Low TTL Thresh High Sink Open Drain Pull Up Enable Output Enable
Read/Write –R/WR/WR/WR/W R/W R/W R/W
Default 00000000
In CY7C602xx this register controls the operation of pins P3.0–P3.1. In the CY7C601xx, this register controls the operation of
pins P3.0–P3.7.
The 50-mA sink drive capability is only available on pin P3.7 and only on the CY7C601xx. In the CY7C602xx, only 8-mA sink
drive capability is available on this pin regardless of the setting of the High Sink bit.
Table 62.P4 Configuration (P4CR) [0x17] [R/W]
Bit # 7 6 5 4 3 2 1 0
Field Reserved Int Enable Int Act Low TTL Thresh High Sink Open Drain Pull Up Enable Output Enable
Read/Write R/W R/W R/W R/W R/W R/W R/W
Default 0 0 0 0 0 0 0 0
This register exists only in the CY7C601xx. This register controls the operation of pins P4.0–P4.3.