Document Number: 001-52038 Rev. *D Page 5 of 21
AC Test Conditions
Figure 3. AC Output Loading
Capacitance
Parameter
[5]
Description Test Conditions Max Unit Conditions
C
IN
Input capacitance T
A
= 25 C, f = 1 MHz, 5 pF V = 0 to 3 V
C
OUT
Output capacitance 7 pF V = 0 to 3 V
Input pulse levels....................................................0 V to 3 V
Input rise and fall times ............................................... <5 ns
Input and output timing reference levels ....................... 1.5 V
Output load........................................................ See Figure 3
480 Ohms
30 pF
255 Ohms
5.0 V
INCLUDING
SCOPE AND
OUTPUT
FIXTURE
Note
5. These
parameters are guaranteed but not tested.
Not Recommended for New Designs