Document Number: 38-08036 Rev. *E Page 26 of 33
AC Programming Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and –40°C <
T
A
< 85°C, or 3.15V to 3.5V and –40°C < T
A
< 85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only.
Table 25. AC Programming Specifications
Parameter Description Min Typ Max Unit Notes
T
RSCLK
Rise Time of SCLK 1 – 20 ns
T
FSCLK
Fall Time of SCLK 1 – 20 ns
T
SSCLK
Data Set up Time to Falling Edge of SCLK 40 – – ns
T
HSCLK
Data Hold Time from Falling Edge of SCLK 40 – – ns
F
SCLK
Frequency of SCLK 0 – 8 MHz
T
ERASEB
Flash Erase Time (Block) – 10 – ms
T
WRITE
Flash Block Write Time – 40 – ms
T
DSCLK
Data Out Delay from Falling Edge of SCLK – – 45 ns Vdd > 3.6
T
DSCLK3
Data Out Delay from Falling Edge of SCLK – – 50 ns 3.15 < Vdd < 3.5
T
ERASEALL
Flash Erase Time (Bulk) – 40 – ms Erase all blocks and
protection fields at once.
T
PROGRAM_HOT
Flash Block Erase + Flash Block Write Time – – 100 ms 0°C ≤ T
J
≤ 100°C
T
PROGRAM_COLD
Flash Block Erase + Flash Block Write Time – – 200 ms -40°C ≤ T
J
≤ 0°C
[+] Feedback
Comentarios a estos manuales