38 CY3240 USB-I2C Bridge Guide, Doc. # 001-66660 Rev.*B
Code Examples
12.In this folder, right-click on ADC10 and select Place. The user module (UM) is placed, as shown
in the following figure.
Figure 5-6. Default ADC User Module Placement
13.The ADC UM is placed in ACE00 and ASE10 of the analog block. Click on Next Allowable
Placement (Figure 5-7) to change the ADC module from ACE00 to ACE01. Click on the Place
User Module icon (Figure 5-7). Similarly, change the ADC module in the digital block from
DBB00 to DCB02, as shown in Figure 5-8.
Figure 5-7. PSoC Designer Toolbar
Figure 5-8. ADC10 User Module Placement
Note A temperature-sensitive voltage, derived from bandgap sensing on the die, is buffered and
available as an analog input into the continuous time block ACE01. So, the ADC module place-
ment is changed to ACE01 block.
Place User Module
Next Allowed Placement